LEED Qualification Guide

How to meet LEED v4

Download the Guide

Sloan is committed to global water conservation and helps our customers worldwide to meet the water and energy challenges of growing businesses, municipalities and communities.

As a member of the United States Green Building Council (USGBC) and through the use of the Leadership in Energy and Environmental Design (LEED) Green Building Rating System, Sloan recognizes and validates the importance of best-in-class building strategies and practices of high performing green buildings. Sloan’s complete line of innovative plumbing solutions can be used to help achieve water efficiency goals as well as gaining USGBC LEED v4 points and/or complying with CAL Green and other building codes.

USGBC’s LEED v4 contains several updates from its predecessor LEED 2009. However the intent of the Water Efficiency (W.E.) section remains the same — to reduce a buildings consumption of potable water. The W.E. section consists of three main components: indoor water (used by fixtures, appliances, and processes), outdoor irrigation water, and total building water metering. Within this section are three prerequisites that specifically requires indoor and outdoor water reductions in addition to documenting the buildings water use. The four W.E. credits rewards a building for achieving specific potable water reduction milestones above the baseline.

Need more information? Tell us what you’re looking for so we can help. Submit your request

LEED Credit Intent Requirement Sloan Solution

W.E. Prerequisite 2

Indoor Water Use Reduction

To reduce indoor water consumption. Reduce aggregate water consumption 20% from the baseline. Sloan HET's & HEU's Sensor faucets 1.28, 1.1 and Reclaimed Water flushometers Pint, Waterfree and Hybrid Urinals.

W.E. Credit 2

Indoor Water Use Reduction (1 to 6 points possible)

To reduce indoor water consumption by greater that 20% above the baseline. Reduce fixture and fitting water use by at least 25% and up to potentially 50%. Points are awarded based on percent reduction achieved. Sloan HET's & HEU's Sensor faucets 1.28, 1.1 and Reclaimed Water flushometers Pint, Waterfree and Hybrid Urinals.

W.E. Prerequisite 3

Building-Level Metering

To support water management and identify opportunities for additional water savings by tracking water consumption. Install permanent water meters that measure the total potable water use for the building and associated grounds and commit to sharing the data with USGBC for a period of 5 years. SMS

W.E. Credit 4

Water Metering (1 point)

To support water management and identify opportunities for additional water savings by tracking water consumption. Install permanent water meters for two or more of the following water subsystems: Irrigation, Indoor plumbing fixtures and fittings, domestic hot water, boilers, reclaimed water and other process water. SMS

BD+C WEp2: Indoor Water Use Reduction

This prerequisite was formerly called the Water Use Reduction prerequisite in LEED 2009. LEED v4’s WE Prerequisite 2 requires the aggregate indoor water consumption be reduced by 20 percent from the baseline. Table 1 identifies the baseline water consumption to be used for various fittings and fixtures when calculating a building’s baseline indoor water use. A v4 update mandates that all newly installed fittings and fixtures that are eligible for the WaterSense label, must have a WaterSense label (or a local equivalent for projects outside the U.S.). The WaterSense label ensures that the fixtures utilized in a LEED building meet both water efficient and high performance testing standards.
Table 1. Baseline Water Consumption Of Fixtures And Fittings.
Fixture or Fitting Baseline IP Units Baseline SI Units
Water Closet (Toilet)* 1.60 gallons per flush 6.00 liters per flush
Urinal* 1.00 gallons per flush 3.80 liters per flush
Public Lavatory Faucet 0.50 gallons/min at 60 psi 1.90 liters/min at 415 kPa
Showerhead* 2.50 gallons/min at 80 psi 9.50 liters/min at 415 kPa

*WaterSense label available for this product type.

BD+C WEp3: Building Level Water Metering

Prerequisite 3 mandates the documentation of a buildings actual potable water consumption. This data must be collected and compiled into monthly and annual reports and submitted to USGBC for a period of at least five years.

BD+C WEc2: Indoor Water Use Reduction

Most of this credit remains from LEED 2009 however the point structure has changed and projects can earn up to a possible six points for reducing potable water consumption by 50%.

Percent reduction

Percent reduction